Your position: Home > Overhead Cable > ACS-Aluminum Clad Steel Wire
ACS-Aluminum Clad Steel Wire
ACS-Aluminum Clad Steel Wire
ACS-Aluminum Clad Steel Wire
ACS-Aluminum Clad Steel Wire

ACS-Aluminum Clad Steel Wire

Aluminum-Clad Steel Wire Strand Conductor is a bimetallic wire which steel wire is covered by Aluminum evenly with advantages of good. electric conductivity, anti corrosion...
Certificate :
ISO 9001 ISO 14001 ISO 45001
Manufacturing Capacity :
10000km/Month
Packaging Details :
Wood Drum, Steel-Wood Drum or Metal Drum
Product Description
Product Application
Product Structure
Main Features
Specification
Related Products
Product Description
Aluminum-Clad Steel Wire Strand Conductor is a bimetallic wire which steel wire is covered by Aluminum evenly with advantages of good. electric conductivity, anti corrosion, good high frequency transmission and high intensity. Aluminum-coated steel core aluminum stranded wire is a stranded wire which strands Aluminum-Clad Steel wire as reinforce core with aluminum wire. It is widely used for electric transmission line conductors, especially for coastal areas, salt alkali beach, grade 3 or grade 4 polluted industrial zone and the place with requirement of enlarged Aluminum steel cross-section ratio.
Get a Custom Quote
Product Application
Aluminum-Clad Steel Wire Strand Conductor is a bimetallic wire which steel wire is covered by Aluminum evenly with advantages of good. electric conductivity, anti corrosion, good high frequency transmission and high intensity. Aluminum-coated steel core aluminum stranded wire is a stranded wire which strands Aluminum-Clad Steel wire as reinforce core with aluminum wire. It is widely used for electric transmission line conductors, especially for coastal areas, salt alkali beach, grade 3 or grade 4 polluted industrial zone and the place with requirement of enlarged Aluminum steel cross-section ratio.
Product Application
Product Application
Product Application
Product Structure
Aluminum-Clad Steel wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the inner layer. Outer layer is right or left hand lay and reversed in successive layers.
ACS-Aluminum Clad Steel Wire
Standard
IEC standard, ASTM standard, and other standard and customizable cable.
Feature
High Tensile Strength, Excellent conductivity–much more conductive than galvanized steel and aluminum.
Specification

Table 1 ASTM B 416

 

Code Number Area No.of wires Diameter Weight Rated Strengh Max.D.C. Resistance at 20℃
Wire Cond.
mm2 mm mm kg/km kN Ω/km
3 N0 5Awg. 50.32 3 4.62 9.96 334.1 54.42 1.699
3 No 6Awg. 39 3 4.11 8.87 265.0 45.74 2.142
3 N0 7Awg. 31.65 3 3.67 7.9 210.1 38.36 2.701
3 No 8Awg. 25.1 3 3.26 7.03 166.7 32.06 3.406
3 N0 9Awg. 19.9 3 2.91 6.26 132.2 25.43 4.294
3 N0 10Awg. 15.78 3 2.59 5.58 104.8 20.16 5.415
7 N0 5Awg. 117.4 7 4.62 13.9 781.l 120.27 0.7426
7 N0 6Awg. 93.1 7 4.11 12.4 619.5 101.14 0.9198
7 N0 7Awg. 73.87 7 3.67 11 491.1 84.81 1.160O
7 No 8Awg. 58.56 7 3.26 9.78 389.6 70.88 1.463
7 N0 9Awg. 46.44 7 2.91 8.71 308.9 56.2 1.844
7 N0 10Awg. 36.83 7 2.59 7.76 245.1 44.58 2.325
7 No l1Awg. 29.21 7 2.3 6.91 194.4 35.35 2.932
7 N0 12Awg. 23.16 7 2.05 6.16 154.2 28.03 3.697
19 No 5Awg. 318.7 19 4.62 23.1 2129.0 326.39 0.2698
19 N0 6Awg. 252.7 19 4.11 20.6 1688.0 274.55 0.3402
19 N0 7Awg. 200.4 19 3.67 18.3 1339.0 230.18 0.429
1g N0 8Awg. 158.9 19 3.26 16.3 1062.0 192.41 0.5409
19 N0 9Awg. 126.1 19 2.91 14.5 842.0 152.58 0.6821
19 N0 10Awg. 99.96 19 2.59 12.9 667.7 121.00 0.8601
37 N0 5Awg. 620.6 37 4.62 32.3 4170.0 635.43 0.1394
37 Na 6Awg. 492.2 37 4.11 28.8 3307.0 534.85 0.1757
37 N0 7Awg. 390.3 37 3.67 25.7 2623.0 448.09 0.2216
37 No aAwg. 309.5 37 3.26 22.9 2080.0 374.67 0.2794
37 N0 9Awg. 245.5 37 2.91 20.3 1649.0 279.11 0.3523
37 N0 10Awg. 194.7 37 2.59 17.9 1308.0 235.61 0.4443
Related Products
To be used for power distribution in medium voltage, as transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations, fixed installed in air, directly buried in the ground or in ducts, where require higher mechanical protection.