Your position: Home > Fire Resistant Cable > CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387
CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387
CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387
CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387
CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387

CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387

The cable is used in fire extinguishing systems, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals, sub-ways, and public facilities.
Certificate :
ISO 9001 ISO 14001 ISO 45001 BS6387 C
Manufacturing Capacity :
500km/Month
Packaging Details :
Wood Drum, Steel-Wood Drum or Metal Drum.
Product Description
Product Application
Product Structure
Main Features
Specification
Related Products
Product Description
The cable is used in fire extinguishing systems, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals, sub-ways, and public facilities.
Get a Custom Quote
Product Application
The cable is used in fire extinguishing systems, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals, sub-ways, and public facilities.
Product Application
Product Application
Product Application
Product Structure
CU/MT/LSZH 0.6/1kV Non-sheathed twisted cable as BS6387 Twisted LSZH insulated non-sheathed fire resistant cable BS 6387
01
Conductor
- Plain annealed class 2 stranded or class 5 flexible copper
02
Fire Resistant Layer
- Mica Tape
03
Insulation
- Low smoke halogen-free (LSZH)
Standard
IEC 60502-1,IEC 60228,BS 6387
Electrical Characteristics:
Rated voltage: 0.6/1 (1.2) kV
High voltage test: 3.5kV / 5min
Temperature characteristics:    
Conductor operating temperature: -15℃~90℃
                   Min. temperature laying condition: 0℃ 
Specification
Related Products
To be used for power distribution in medium voltage, as transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations, fixed installed in air, directly buried in the ground or in ducts, where require higher mechanical protection.