Your position: Home > Low Voltage Power Cable > 0.6/1kV PVC Insulation Unarmored Power Cable
0.6/1kV PVC Insulation Unarmored Power Cable
0.6/1kV PVC Insulation Unarmored Power Cable
0.6/1kV PVC Insulation Unarmored Power Cable
0.6/1kV PVC Insulation Unarmored Power Cable

0.6/1kV PVC Insulation Unarmored Power Cable

To be used for main power supply, In low voltage distribution power networks, industrial installations, in buildings and operation stations. fixed installation in the ground or in concrete...
Certificate :
ISO 9001 ISO 14001 ISO 45001 CE
Manufacturing Capacity :
5000km/Month
Packaging Details :
Wood Drum, Steel-Wood Drum or Metal Drum
Product Description
Product Application
Product Structure
Main Features
Specification
Related Products
Product Description
To be used for main power supply, In low voltage distribution power networks, industrial installations, in buildings and operation stations. fixed installation in the ground or in concrete, in the cable trenches or cable, ducts, indoor or outdoor areas, in dry or wet locations.
Get a Custom Quote
Product Application
To be used for main power supply, In low voltage distribution power networks, industrial installations, in buildings and operation stations. fixed installation in the ground or in concrete, in the cable trenches or cable, ducts, indoor or outdoor areas, in dry or wet locations.
Product Application
Product Application
Product Application
Product Structure
0.6/1kV PVC Insulation Unarmored Power Cable
01
Conductor
- Plain annealed class 2 stranded (compacted) copper
02
Insulation
- Polyvinyl chloride compound (PVC)
03
Filler
- Non-hygroscopic material(For Multi-core)
04
Binder Tape
- Non-hygroscopic material tape(For Multi-core)
05
Outer Sheath
- Polyvinyl chloride compound (PVC)
Standard
IEC 60502-1 or AS/ZNS 5000.1 or custom cable
Conductor: IEC 60228 or AS/ZNS 1125
Temperature Characteristics
Conductor operating temperature: -15℃~70℃
                  Min. temperature laying condition: 0℃
                Conductor short-circuit operating temperature (5s): 160℃(≤300mm2) 140℃(>300mm2)
Specification

Table 1 Single core CU/PVC/PVC IEC 60502-1

 

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
Phase Earth Phase Earth
mm mm mm mm mm mm kg/km
1C1.5 1.56 / 0.8 / 1.4 6 52.1
1C2.5 2.04 / 0.8 / 1.4 6.5 65.9
1C4 2.55 / 1 / 1.4 7.5 91.4
1C6 3.1 / 1 / 1.4 8 115.3
1C10 4 / 1 / 1.4 8.9 159.1
1C16 5 / 1 / 1.4 9.9 222.3
1C25 6.1 / 1.2 / 1.4 11.4 325.7
1C35 7.2 / 1.2 / 1.4 12.5 423.5
1C50 8.4 / 1.4 / 1.4 14.1 557.5
1C70 10 / 1.4 / 1.4 15.7 763
1C95 12 / 1.6 / 1.5 18.4 1046.5
1C120 13 / 1.6 / 1.5 19.4 1277.4
1C150 14.9 / 1.8 / 1.6 21.9 1581.5
1C185 16.5 / 2 / 1.7 24.1 1956.5
1C240 18.4 / 2.2 / 1.8 26.6 2537.3
1C300 21 / 2.4 / 1.9 29.8 3164.4
1C400 23.4 / 2.6 / 2 32.9 4022.4
1C500 26.6 / 2.8 / 2.1 36.7 5111.8
1C630 30 / 2.8 / 2.2 40.3 6445.8
1C800 34 / 2.8 / 2.3 44.5 8137.1

 

Table 2 Two core CU/PVC/PVC IEC 60502-1

 

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
Phase Earth Phase Earth
mm mm mm mm mm mm kg/km
2C1.5 1.56 / 0.8 / 1.8 10.7 128.5
2C2.5 2.04 / 0.8 / 1.8 11.6 161
2C4 2.55 / 1 / 1.8 13.5 222.4
2C6 3.1 / 1 / 1.8 14.6 277.2
2C10 4 / 1 / 1.8 16.4 377.5
2C16 5 / 1 / 1.8 18.4 519.5
2C25 6.1 / 1.2 / 1.8 21.4 753.6
2C35 7.2 / 1.2 / 1.8 23.6 971.5
2C50 8.4 / 1.4 / 1.8 26.9 1275.8
2C70 10 / 1.4 / 1.9 30.9 1754.1
2C95 12 / 1.6 / 2 35.9 2393.8
2C120 13 / 1.6 / 2.1 38.1 2907.7
2C150 14.9 / 1.8 / 2.2 43 3600.9
2C185 16.5 / 2 / 2.4 47.4 4455
2C240 18.4 / 2.2 / 2.6 52.4 5747.9
2C300 21 / 2.4 / 2.7 58.7 7156

 

Table 3 Three core CU/PVC/PVC IEC 60502-1

 

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
Phase Earth Phase Earth
mm mm mm mm mm mm kg/km
3C1.5 1.56 / 0.8 / 1.8 11.2 154.2
3C2.5 2.04 / 0.8 / 1.8 12.2 197.7
3C4 2.55 / 1 / 1.8 14.2 279
3C6 3.1 / 1 / 1.8 15.4 354.4
3C10 4 / 1 / 1.8 17.4 492.9
3C16 5 / 1 / 1.8 19.5 691.8
3C25 6.1 / 1.2 / 1.8 22.8 1019.1
3C35 7.2 / 1.2 / 1.8 25.2 1327.3
3C50 8.4 / 1.4 / 1.8 28.7 1753.8
3C70 10 / 1.4 / 2 33.2 2442.5
3C95 12 / 1.6 / 2.1 38.6 3341.9
3C120 13 / 1.6 / 2.2 40.9 4081.1
3C150 14.9 / 1.8 / 2.3 46.1 5051.4
3C185 16.5 / 2 / 2.5 50.9 6255.4
3C240 18.4 / 2.2 / 2.7 56.3 8099.7
3C300 21 / 2.4 / 2.9 63.2 10121

 

Table 4 Four core CU/PVC/PVC IEC 60502-1

 

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
Phase Earth Phase Earth
mm mm mm mm mm mm kg/km
4C1.5 1.56 / 0.8 / 1.8 12 184.8
4C2.5 2.04 / 0.8 / 1.8 13.2 240.4
4C4 2.55 / 1 / 1.8 15.5 344.1
4C6 3.1 / 1 / 1.8 16.8 441.7
4C10 4 / 1 / 1.8 19 621.3
4C16 5 / 1 / 1.8 21.4 880.7
4C25 6.1 / 1.2 / 1.8 25.1 1307.7
4C35 7.2 / 1.2 / 1.8 27.7 1711.4
4C50 8.4 / 1.4 / 1.9 31.8 2283.2
4C70 10 / 1.4 / 2.1 36.7 3181.4
4C95 12 / 1.6 / 2.2 42.8 4358.5
4C120 13 / 1.6 / 2.4 45.6 5352.4
4C150 14.9 / 1.8 / 2.5 51.4 6623.4
4C185 16.5 / 2 / 2.7 56.7 8201.1
4C240 18.4 / 2.2 / 2.9 62.7 10626.5
4C300 21 / 2.4 / 3.1 70.4 13276

 

Table 5 Five core CU/PVC/PVC IEC 60502-1

 

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
Phase Earth Phase Earth
mm mm mm mm mm mm kg/km
5C1.5 1.56 / 0.8 / 1.8 12.9 217.1
5C2.5 2.04 / 0.8 / 1.8 14.2 285.2
5C4 2.55 / 1 / 1.8 16.8 412.1
5C6 3.1 / 1 / 1.8 18.2 532.5
5C10 4 / 1 / 1.8 20.7 754.5
5C16 5 / 1 / 1.8 23.4 1075.7
5C25 6.1 / 1.2 / 1.8 27.5 1605.1
5C35 7.2 / 1.2 / 1.9 30.6 2120.2
5C50 8.4 / 1.4 / 2.1 35.4 2846.2
5C70 10 / 1.4 / 2.2 40.5 3942.6
5C95 12 / 1.6 / 2.4 47.5 5426.9
5C120 13 / 1.6 / 2.5 50.4 6639.2
5C150 14.9 / 1.8 / 2.7 57 8243.7
5C185 16.5 / 2 / 2.9 62.9 10204.8
5C240 18.4 / 2.2 / 3.1 69.6 13223.2
5C300 21 / 2.4 / 3.3 78.1 16518.2
Related Products
To be used for power distribution in medium voltage, as transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations, fixed installed in air, directly buried in the ground or in ducts, where require higher mechanical protection.